HITCH & LOAD PLANNING
Rigging Calculator & 3D Planner
Choose the load. Build the rig. Explore every angle.
Live 3D geometry
Geometry · Hitches · Load cases
YOUR LOAD LIBRARY
Start with the right shape.
No matching load. Try another name or category.
LIVE WORKSPACE
The rigging view.
Node-centre scaffold geometry
Routed sling lengths appear below| Segment | Length | θ horizontal | β vertical |
|---|
The geometry view shows node-centre measurements. Open Hitch & Load below for supported calculations, entered ratings and unresolved checks.
HITCH & LOAD CALCULATION
Give the geometry its data.
Enter the load, record each sling and compare supported static cases with the rating you supply.
θ is measured from horizontal, β from vertical, α between branches, and χ at the choke. A physical basket sling has two loaded branches. Unsupported cases stay visible and unassessed.
For a worked example, open the Two-Leg Sling Tension Calculator or the Sling Length & Headroom Calculator.
Model & gear references
The models show generic geometry. Enter the dimensions, lifting-point positions, mass, COG and gear data for your actual load. Dimensions from an example catalogue do not establish a fitting match.
- Rebar: Chua Tong Hin straight bar · Southern Steel product standards
- Precast: LTH culvert, drain and manhole catalogue · OKA square piles
- Containers: Hapag-Lloyd container fleet · ISO 668 size classification · ISO 1161 corner fittings
- Data centre & MEP: ABB eHouse · Schneider Electric power modules and skids · Trane AHU · Grundfos Hydro MPC pump skid
- Rigging gear: Dayton Superior clutch and anchor · Camlok container lifting lugs · Crosby vertical clamp · Crosby horizontal clamp · ICSA equalizer beam guidance
Method & references
Each reported sling segment joins two explicit node centres. Length = √(ΔX² + ΔY² + ΔZ²). θ = atan2(ΔY, √(ΔX² + ΔZ²)), measured from the horizontal plane; β is measured from vertical. α denotes an included angle between branches, while χ denotes the local choke angle; they are reported only where that definition applies. Upper and lower sling segments are listed separately. Moving an attachment, beam or hook changes the geometric length.
Direct bridles converge at one common hook. Spreader beams use two upper picks; lifting beams use a single central upper pick; four-point frames use four upper picks. These are schematic geometry arrangements. Hardware sizes are visual references, and node-centre lengths include hardware symbols. Aligning the hook above the COG does not calculate equilibrium or prove stability. Displayed legs do not imply equal load sharing. Enter actual project/OEM attachment data; this tool does not approve lifting points, hardware selection or lift execution.
Rigging background: Crosby historical sling-angle reference ↗ · Unirope: centre of gravity ↗